Live ECG Streaming, HRV Engine & Clinical Report

Working telemetry pipeline capturing 512 SPS single-lead ECG and Bio-Z respiration, executing automated HRV spectral/nonlinear analysis, and generating Cardiology Record PDFs.

STREAM 01 // REAL-TIME ECG + BIO-Z

Live ECG Waveform & Edge TCN Telemetry

512 SPS TI AFE4960 acquisition with CMSIS-DSP causal biquad filtering, live Lead II ECG, Bio-Z respiration sweep, and on-device Axon NPU TCN classification.

STREAM 02 // HRV & ANS ENGINE

Automated HRV Analysis & Poincaré Dynamics

Continuous R-R interval tachogram, time-domain & frequency-domain spectral power (VLF/LF/HF), and nonlinear SD1/SD2 Poincaré autonomic balance analysis.

CLINICAL OUTPUT // BIOVIEW HRV REPORT

Automated Holter & HRV Clinical Report

Every study automatically compiles into a standardized Cardiology Record PDF alongside European Data Format (EDF) and HL7/FHIR R4 payloads for hospital EMR ingestion.

Patient / Bed
P-0482 · BED-04 [ICU-A]
Beats Analyzed
840 beats @ 250 Hz
Mean RR / HR
924.4 ms · 64.9 bpm
SDNN / RMSSD
181.4 ms · 38.6 ms
LF / HF Ratio
2.32 (Total 5505.1 ms²)
Poincaré SD1 / SD2
27.3 ms / 255.0 ms
Open Source PDF

Telemetry Demo

BioView HRV Clinical Report — Patient P-0482

Full-resolution BioView HRV Clinical Report

Quantized TCN with Deterministic Edge Gating

On-device 7-layer dilated convolutional network gating BLE transmissions to eliminate cellular data waste.

Stage 01

1000SPS Acquisition

Continuous sampling on TI AFE4960 with CMSIS-DSP causal biquad filtering.

Stage 02

250 Buffer Slicing

2.0-second rolling window feeding local R-R dynamics directly to Axon NPU.

Stage 03

INT8 Axon Inference

7-layer residual TCN completes inference in under 3 ms at microamp draw.

Stage 04

Gated Transmission

Radio sleeps >95% of cycle, waking solely on confirmed ventricular anomalies.

Model Footprint
<90 KB

Fits in 512 KB internal SRAM

NPU Duty Cycle
<0.5%

Sub-3 ms active execution window

VEB Ectopy F1
87.7%

98.9% specificity on DS2 benchmark

Cellular Data Cut
>90%

Slashes SIM fees & cloud ingestion

Clinical-Grade Analog Engine & Interoperable SaaS

Miniaturized 4-layer HDI PCB paired with cloud neural verification, automated EDF reporting, and native EMR ingestion.

Analog Front-End

TI AFE4960 IC

512 SPS single-lead ECG with bio-impedance respiration and hardware pace detection.

Processing Core

Nordic nRF54LM20B

128 MHz ARM Cortex-M33 paired with Axon NPU and BLE 5.4 radio engine.

Non-Volatile Memory

4Gb SLC NAND Flash

1.8V Quad-SPI storage with internal hardware ECC and LittleFS wear-leveling.

Physical Profile

Waterproof Patch

IPX7 enclosure with dual parallel CR2450 cells and 3M biocompatible adhesive.

PCB Stackup & Rail
4-Layer HDI · 1.8V Native

POFV via-in-pad with isolated AGND/DGND and zero level-shifters to maximize battery efficiency.

Firmware Runtime
Rust / Zephyr (IEC 62304)

Memory-safe driver architecture eliminating buffer overflows for Class B medical firmware.

Enterprise SaaS
HL7 / FHIR R4 & HIPAA/GDPR

Cloud-neutral hospital VPC deployment, automated EDF exports, and Epic/Cerner EMR ingestion.